HPLC Column, HPS Silica, 5um, 4.6mm ID x 50mm Length, 120A. Cogent Brand. 1 EA.
Additional Info:
75001-05P Cogent HPS Silica™ HPLC Column is packed with a high‑purity, unmodified silica stationary phase, offering reliable and reproducible performance for normal phase chromatography and USP L3 classified methods.
Because the silica is not chemically modified, it provides strong interaction with polar and hydrophilic compounds, making it ideal for separations involving fats, lipids, and other polar analytes.
This proprietary HPS Silica™ has been widely adopted in analytical laboratories as a dependable and cost‑effective alternative to traditional silica columns such as Inertsil® and Luna®, delivering consistent selectivity and performance.
The 5 µm particle size ensures a balance of efficiency and durability, allowing operation at higher flow rates with lower backpressure, making it well suited for routine analytical methods on standard HPLC systems.
50 mm Length – Fast Normal Phase Separations
The 50 mm column length is optimized for speed and throughput.
Shorter run times for rapid analysis
Reduced solvent consumption
Ideal for method development and screening
✅ Recommended for high‑throughput normal phase HPLC workflows
4.6 mm ID – Standard Analytical HPLC Format
Designed for 4.6 mm ID analytical columns
Robust and widely compatible with standard HPLC systems
Higher sample loading vs narrower ID columns
Well suited for routine analytical methods
✅ Recommended for QC labs and general-purpose analytical HPLC
Flow Rate & System Requirements (4.6 mm ID, 5 µm)
✅ Compatible with standard HPLC systems
Typical flow rate range: ~1.0 – 1.5 mL/min
Lower backpressure vs smaller particle columns
Suitable for routine analytical separations
Compatible with UV and other standard detectors
✅ Best Practice: Optimize mobile phase composition for normal phase retention and reproducibility
Why Choose HPS Silica™ Columns
High‑Purity Unmodified Silica
Ideal for normal phase chromatography
Strong retention of polar compounds
USP L3 Compatibility
Suitable for compendial methods
Reliable alternative to legacy silica columns
Consistent Performance
Reproducible selectivity
Proven long-term reliability
Performance Advantages
Low Backpressure (5 µm Particles)
Enables higher flow rates
Compatible with conventional systems
Fast Equilibration
Reduces downtime between runs
Excellent for Polar Analytes
Ideal for lipids, fats, and hydrophilic compounds
Typical Applications
Fats and lipid analysis
Normal phase HPLC separations
Polar compound analysis
USP L3 method applications
Food, pharmaceutical, and chemical testing
Important Usage Notes
Designed for normal phase chromatography conditions
Use appropriate non‑polar mobile phases (e.g., hexane-based systems)
Ensure proper system equilibration for reproducible retention
Follow standard silica column handling procedures